| ATEX |
LHL |
Armatura illuminante portatile |
II 2G Ex e mb IIC T... (Gb) II 2D Ex mb IIIC T…°C (Db) |
Cortem |
|
| ATEX |
G-0309 |
Gruppo batterie |
Ex II 2G Ex e IIC Gb
|
Cortem |
|
| ATEX |
EJB-...AQS-1 |
Componente |
II 2GD Ex db IIB+H2 Gb I M2 Ex db I Mb (EJBX) Ex tb IIIC Db |
Cortem |
|
| ATEX |
SP |
Tubi flessibili |
II 2GD Ex d IIB Gb Ex tb IIIC Db II 2GD Ex d IIC Gb Ex tb IIIC Db |
Elfit |
|
| ATEX |
M-0459, M-0487, M-0612 |
LED di segnalazione |
II 2GD Ex de IIC Gb Ex tb IIIC Db II 2GD Ex d IIC Gb Ex tb IIIC Db |
Cortem |
|
| ATEX |
M-0... |
Manovre - CESI |
II 2GD Ex d IIC Ex td A21 I M2 Ex d I Mb |
Cortem |
|
| ATEX |
EJB-...AQS-1 |
Conformità |
II 2GD Ex db IIB+H2 T.. Gb Ex tb IIIC T..°C Db |
Cortem |
|
| ATEX |
GUB... CCA... |
Componente |
I M2 Ex db I Mb II2GD Ex db IIC Gb Ex tb IIIC Db |
Cortem |
|
| ATEX |
GUB... CCA... |
Conformità |
Ex I M2 Ex db I Mb Ex II 2GD Ex db IIB T.. Gb Ex tb IIIC T.. Db
|
Cortem |
|
| ATEX |
CP,TP,NPS,NCS,LPS |
Passanti sigillati |
II 2G Ex Db IIC Gb |
Elfit |
|
| ATEX |
CSC...EFDC...EFSCO...EMH... |
Pulsantiere di comando, controllo e segnalazione |
I M2 Ex db I Mb II 2 GD Ex db IIC T6 T5 Gb Ex tb IIIC T85°C T100°C Db |
Cortem |
|
| ATEX |
NP,EM,ELF,ELMF,ELM |
Raccorderia |
II 2GD Ex d IIC Gb Ex e IIC Gb Ex tb IIIC Db |
Elfit |
|
| ATEX |
S,S.1,GUA,GUF,EAH |
Scatole portamorsetti |
II 2GD Ex d IIC T… Ex tD A21 T… II 2GD Ex e II T… Ex tD A21 T… II 2(1) GD Exi. IIC T… Ex tD A21 T… II 2(1) GD Ex d[ia] IIC T… Ex tD A21 T… |
Elfit |
|
| ATEX |
RE,REB,REM,REN,PLG |
Tappi e adattatori |
II 2GD Ex d IIC Gb Ex e IIC Gb Ex tb IIIC Db |
Elfit |
|
| ATEX |
EJB-...AQS-1 |
Conformità e unità d'interfaccia (barriere) |
Ex d [ia Ga] IIB+H2 T5/T6 Gb Ex d [ia Ga] IIB+H2 T5/T6 Gb Ex tb [ia Da] IIIC T85°C T100°C Db |
Cortem |
|
| ATEX |
S,S.1,GUA,GUF,EAH |
Scatole portamorsetti |
II 2GD Ex d IIC T… Gb Ex tb IIIC T… Db II 2GD Ex e IIC T… Gb Ex tb IIIC T… Db II 2 GD Exi IIC T… Gb Ex tb IIIC T… Db |
Cortem |
|
| ATEX |
EJB..SC |
Scaricatori |
II 2GD Ex d IIB+H2 T5/T6 Ex tD A21 T85°C T100°C |
Cortem |
|
| ATEX |
S,S.1,GUA,GUF,EAH |
Scatole vuote |
II 2GD Ex d IIC Gb Ex tb IIIC Db |
Elfit |
|
| ATEX |
XLF |
Arm.segnalazione ostacoli |
II 2GD Ex d IIC T… Ex tb IIIC T... Db II 2GD Ex de IIC T… Gb Ex tb IIIC T... Db |
Cortem |
|
| ATEX |
S,S.1,GUA,GUF,EAH |
Scatole vuote |
II 2GD Ex d IIC Gb Ex tb IIIC Db |
Cortem |
|
| ATEX |
EYS,EZS,EYD,EZD |
Raccordi di bloccaggio |
Ex II 2GD Ex db IIC Gb Ex tb IIIC Db |
Elfit |
|
| ATEX |
SA... CTB |
Unità comando e controllo |
II 2GD Ex de IIC T… Gb Ex tb IIIC T… Db |
Cortem |
|
| ATEX |
LBH, LBHS, EKC |
Curve apribili e raccordi dritti apribili |
II 2G Ex d IIB |
Elfit |
|
| ATEX |
CSE... EFD3... |
Unità di controllo e segnalazione |
II 2GD Ex d IIB T5/T6 Ex tD A21 |
Cortem |
|
| ATEX |
GUB... CCA... |
Unità d’interfaccia (barriere) |
I M2 Ex d [ia Ma] I Mb II2(1)GD Ex d [ia Ga] IIC T… Gb Ex tb [ia Da] IIIC T…°C Db |
Cortem |
|
| ATEX |
PMT-B2 |
Pinza di messa a terra |
II 2GD Ex d IIC T6 Ex tD A21 |
Cortem |
|
| ATEX |
GUAB37TE |
Termostato |
II 2 GD Ex d IIC T6 Ex tD A21 |
Elfit |
|
| ATEX |
SA... SAG... SA.../P SA...SS CTB... CTBE... |
Cassette con morsetti |
II 2GD Ex e IIC T… Gb Ex tb IIIC T… Db II 2GD Ex ia IIC T… Gb Ex ia IIIC T… Db II 2GD Ex e ia IIC T… Gb Ex tb ia IIIC T… Db |
Cortem |
|
| ATEX |
B-0140A, B-0140V |
Amperometro e voltmetro |
II 2GD Ex e IIC Gb Ex tb IIIC Db |
Cortem |
|
| ATEX |
GRD-4200 |
Sistema di messa a terra |
II 2(1) GD Ex d [ia Ga] ia IIB + H2 T6 Gb Ex d [ia Ga] ia IIB+H2 T6 Gb II 2(1)D Ex tb [ia Da] ia IIIC T85°C Db |
Cortem |
|
| ATEX |
TIGER |
Proiettori |
II 3GD Ex nR IIC T… Gc Ex tc IIIC T… Dc |
Cortem |
|
| ATEX |
FLFE...FLF... |
Armature illuminanti |
II 2GD Ex db eb op is IIC T6 Gb Ex tb op is IIIC T… Db |
Cortem |
|
| ATEX |
FLFE...FLF... |
Armature illuminanti |
II 2GD Ex db op is IIC T6 Gb Ex tb op is IIIC T… Db |
Cortem |
|
| ATEX |
M-0530, M-0531 |
Blocco contatti |
II 2G Ex de IIC Gb |
Cortem |
|
| ATEX |
FHL |
Armature illuminanti portatili |
II 2GD Ex d IIC T6 Gb Ex tb IIIC T85°C Db |
Cortem |
|
| ATEX |
M-0603, M-0604, M-0605 |
Attuatori di comando |
II 2GD Ex e IIC Gb Ex tb IIIC Db |
Cortem |
|
| ATEX |
EV,EW,EWA,EVE,EWE,EWAE |
Armature illuminanti serie 5 |
II 2GD Ex d IIC T… Gb (EV EW EWA) Ex tb IIIC T… Db (EV EW EWA) II 2GD Ex de IIC T… Gb (EVE EWE EWAE) Ex tb IIIC T… Db (EVE EWE EWAE) |
Cortem |
|
| ATEX |
EJBE, EJBXE |
Pannello di controllo |
II 2(1)GD Ex de [ia Ga] IIB+H2 T5/T6 Gb Ex tb [ia Da] IIIC T85°C T100°C Db |
Cortem |
|
| ATEX |
GUBE |
Quadri di controllo |
II 2GD Ex de IIC T… Gb Ex tb IIIC T… Db |
Cortem |
|
| ATEX |
EJBE, EJBXE |
Custodie vuote |
II 2 GD Ex de IIB+H2 Gb Ex tb IIIC Db |
Cortem |
|
| ATEX |
BMF, BFF, BMM, RMF, RFF, RMM |
Raccordi di collegamento |
II 2GD Ex d IIB Gb Ex tb IIIC Db II 2GD Ex d IIC Gb Ex tb IIIC Db |
Elfit |
|
| ATEX |
CCA-03EX |
Lighting fixtures for safety warnings |
II 2GD Ex d IIC T6 Gb Ex tb IIIC T85°C Db |
Cortem |
|
| ATEX |
ECDE |
Drain valves |
II 2GD Ex eb IIC Gb Ex tb IIIC Db |
Cortem |
|
| ATEX |
EBL3040-1,EBL4040-2,EIL4040-1,EIF4040-1 |
Reattore e inverter |
II 2 G Ex db IIC Gb |
Cortem |
|
| ATEX |
M-0… |
Operatori di comando, controllo e segnalazione |
Il 2D Ex tb IIIC Db |
Cortem |
|
| ATEX |
SA,CTB,CTBE |
Unità comando e controllo Ex tb |
Il 2D Ex tb IIIC T80°C Db |
Cortem |
|
| ATEX |
LFEE |
Armature illuminanti d'emergenza |
II 2GD Ex db eb mb op is IIC T... Gb Ex tb op is IIIC T... Db |
Cortem |
|
| ATEX |
EVML |
Armatura illuminante |
II 2GD Ex eb mb op is IIC T.. Gb Ex tb op is IIIC T.. Db |
Cortem |
|
| ATEX |
EVL |
Armatura illuminante |
II 2GD Ex db eb op is IIC T.. Ex tb op is IIIC T..°C Db |
Cortem |
|
| ATEX |
NAVB NEVB |
Pressacavi barriera |
II 2G Ex db IIC Gb Ex eb IIC Gb II 2D Ex tb IIIC Db II 2GD Ex db IIC Gb Ex eb IIC Gb Ex tb IIIC Db |
Cortem |
|
| ATEX |
NAVB NEVB |
Pressacavi barriera |
II 3G Ex nR IIC Gc |
Cortem |
|
| ATEX |
XLFE-MIB, XLFE-MIA, XLFE-LIB, XLFE-MIC |
Armatura segnalazione ostacoli |
II 2GD Ex db eb op is IIC T.. Gb Ex tb op is IIIC T..°C Db |
Cortem |
|
| ATEX |
UN..4,PLG..4,UN..7,NAVP,PLG..7,PT |
Cableglands and plugs |
II 2 GD Ex eb IIC Gb Ex tb IIIC Db |
Cortem |
|
| ATEX |
LIFEX-MN |
Armatura illuminante |
LIFEX-MN II 3 G Ex ec IIC T... Gc
|
Cortem |
|
| ATEX |
LIFEX-ME |
Armatura illuminante |
LIFEX-ME II 2 GD Ex db eb mb IIC T…Gb Ex tb IIIC T…°C Db IP66 LIFEX-MN II 2 D Ex tb IIIC T…°C Db IP66 |
Cortem |
|
| INMETRO |
S,S.1,GUA,GUF,EAH |
Cassette di derivazione |
Ex d IIC Ex e IIC Ex ia/ib IIC Ex tb
|
Cortem |
|
| INMETRO |
EJB |
Custodie di comando, controllo e segnalazione |
Ex db I Mb Ex db IIB+H2 T..Gb Ex tb IIIC T.. Db
|
Cortem |
|
| INMETRO |
GUB |
Cassette di derivazione |
Ex db [ia Ma] I T.. Mb Ex db [ia Ga] IIC Gb Ex tb [ia Da] IIIC T.. Db
|
Cortem |
|
| INMETRO |
SA... CTB |
Cassette di derivazione |
Ex eb ia IIC T.. Gb Ex ia tb IIIC T.. Db
|
Cortem |
|
| INMETRO |
PLG |
Tappi |
Ex db IIC Gb Ex eb IIC Gb Ex tb IIIC Db
|
Cortem |
|
| INMETRO |
EYS, EZS,EYD |
Raccorderia |
Ex db IIC Gb Ex tb IIIC Db |
Cortem |
|
| INMETRO |
NP,EM,ELF,ELMF,ELM |
Raccorderia |
Ex db IIC Gb Ex eb IIC Gb Ex tb IIIC Db
|
Cortem |
|
| INMETRO |
SA... CTB |
Cassette di derivazione |
Ex eb IIC Gb Ex tb IIIC Db
|
Cortem |
|
| INMETRO |
EJB, EJBX |
Cassette di derivazione |
Ex db I Mb Ex db IIB+H2 Gb Ex tb IIIC Db
|
Cortem |
|
| INMETRO |
M-0 |
Operatori di comando |
Ex d I Mb Ex d IIC Gb Ex tb IIIC Db IP66 |
Cortem |
|
| INMETRO |
BMF, BFF, BMM, RMF, RFF, RMM |
Three-pieces union |
Ex db IIB Gb Ex db IIC Gb Ex tb IIIC Db
|
Cortem |
|
| INMETRO |
M-0603, M-0604, M-0605 |
Operatori di comando |
Ex eb IIC Gb Ex tb IIIC Db
|
Cortem |
|
| INMETRO |
EVNL |
Armature illuminanti e proiettori |
Ex nR IIC T.. Gc Ex tb op is IIIC T.. Db Ex tc IIIC T.. Dc
|
Cortem |
|
| INMETRO |
LIFEX-M |
Armature illuminanti |
Ex db eb mb IIC T.. Gb Ex ec IIC T.. Gc Ex tb IIIC T.. Db
|
Cortem |
|
| ATEX |
LFED |
Armature illuminanti d'emergenza |
II 2GD Ex db op is IIB+H2 T6 Ex tb op is IIIC T72°C Db |
Cortem |
|
| UL |
SX7E.. SX9E.. |
|
Class I Groups C and D Class II Groups E F and G |
Cortem |
|
| IECEx |
SA,CTB,CSTB,CTBE |
Unità comando e controllo |
Ex tb IIIC T80°C Db |
Cortem |
|
| IECEx |
EV... EW... EWA... EVE... EWE... EWAE... |
Armature illuminanti |
Ex d IIC T6 to T3 Gb Ex de IIC T6 to T3 Gb Ex tb IIIC T54°C to T185°C |
Cortem |
|
| IECEx |
RE, REB, REM, REN, EM, NP, PLG |
Adattatori, tappi, manicotti, nippli |
Ex d IIC Ex e II Ex td A21 |
Cortem |
|
| IECEx |
BMF, BFF, BMM, RMF, RFF, RMM |
Raccordi a 3 pezzi |
II 2GD Ex d IIC Ex td A21 |
Cortem |
|
| IECEx |
CP,TP,NPS,NCS,LPS |
Passanti sigillati |
Ex db IIC Gb Ex tb IIIC Db (NPS only) |
Cortem |
|
| IECEx |
FLFE...FLF… |
Armature Illuminanti |
II 2GD Ex db eb IIC T6 Gb Ex tb IIIC T...°C Db |
Cortem |
|
| IECEx |
FLFE...FLF… |
Armature Illuminanti |
II 2GD Ex db eb IIC T6 Gb Ex tb IIIC T...°C Db |
Cortem |
|
| IECEx |
M-0603, M-0304, M-0605 |
Operatori Ex e |
Ex e IIC Gb Ex tb IIIC Db |
Cortem |
|
| IECEx |
M-0612, M-0487 |
Spie led |
Ex d IIC Gb Ex de IIC Gb Ex tb IIIC Db |
Cortem |
|
| IECEx |
M-0530, M-0531 |
Contatti Ex de |
Ex de IIC Gb |
Cortem |
|
| IECEx |
SA... CTB |
Unità comando e controllo |
Ex de IIC T6 T5 Ex tb IIIC T85°C or T100°C Db |
Cortem |
|
| IECEx |
EJBE, EJBXE |
Pannelli di controllo |
Ex de IIB+H2 T6 T5 Gb Ex tb IIIC T85°C T100°C Db Ex d e [ia Ga] IIB+H2 T6 T5 Gb Ex tb [ia Da] IIIC T85°C T100°C Db |
Cortem |
|
| IECEx |
XLF, XLFE |
Segnalazione ostacoli |
Ex d IIC T5 T6 Gb (XLF) Ex tb IIIC T52°C or T87°C Db (XLF) II 2GD Ex de IIC T5 T6 (XLFE) Ex tb IIIC T52°C-T87°C Db (XLFE) |
Cortem |
|
| IECEx |
GUBE |
Quadri di controllo |
Ex de IIC T6 T5 Gb Ex tb IIIC T85°C or T100°C Db |
Cortem |
|
| IECEx |
SA... SAG... SA.../P SA...SS CTB... CTBE... |
Cassette porta morsetti |
Ex e IIC T5 T6 Ex tb IIIC T85°C or T100°C Db Ex ia IIC T5 T6 Gb Ex ia IIIC T85°C or T100°C Db Ex e ia IIC T5 T6 Ex tb ia IIIC T85°C or T100°C Db |
Cortem |
|
| IECEx |
G-0309 |
Gruppo batterie |
Ex e IIC Gb |
Cortem |
|
| IECEx |
SP |
Tubi flessibili |
Ex II 2GD Ex d IIC Gb Ex d IIB Gb Ex tb IIIC Db |
Cortem |
|
| IECEx |
GUB... CCA... |
Componente |
Ex db I Mb Ex db IIC Gb Ex tb IIIC Db |
Cortem |
|
| IECEx |
CA-8.2-50 |
Barriere sicurezza intrinseca |
[Ex ia Ga] IIC [Ex ia Da] IIIC |
Cortem |
|
| IECEx |
ECD… |
Valvoline |
II 2 G Ex d IIC Gb (ECD-1...) II 2 G Ex d IIB Gb (ECD-1...) II 2 GD Ex d IIC Gb (ECD-2…) Ex e IIC Gb (ECD-2) Ex tb IIIC Db (ECD-2...) II 2 GD Ex d IIB Gb - Ex e IIB Gb - Ex tb IIIC Db (ECD-2...) |
Cortem |
|
| IECEx |
EJB-…AQS-1 |
Componente |
Ex db I Mb Ex db IIB+H2 Gb Ex tb IIIC Db |
Cortem |
|
| IECEx |
S,S.1,GUA,GUF,EAH |
Cassette portamorsetti |
Ex d IIC Gb Ex e IIC Gb Ex i. IIC Gb Ex tb IIIC Db |
Cortem |
|
| IECEx |
EYS,EZS,EYD,EZD |
Raccordi di bloccaggio |
Ex d IIC Gb Ex tb IIIC Db |
Cortem |
|
| IECEx |
M-0... |
Manovre |
Ex db I Mb Ex db IIC Gb Ex tb IIIC Db |
Cortem |
|
| IECEx |
GRD-4200 |
Grounding system |
II 2(1) GD Ex d [ia Ga] ia IIB + H2 T6 Gb Ex d [ia Ga] ia IIB+H2 T6 Gb II 2(1)D Ex tb [ia Da] ia IIIC T85°C Db |
Cortem |
|
| IECEx |
NP,EM,ELF,ELMF,ELM |
Raccorderia |
Ex d IIC Gb Ex e IIC Gb Ex tb IIIC Db |
Cortem |
|
| IECEx |
S,S.1,GUA,GUF,EAH |
Cassette vuote |
Ex d IIC Gb Ex tb IIIC Db |
Cortem |
|
| IECEx |
EJBE, EJBXE |
Componente |
Ex de IIB+H2 Gb Ex tb IIIC Db |
Cortem |
|
| IECEx |
EJB-…AQS-1 |
Cassette per unità di segnalazione comando e controllo |
Ex db I Mb (only EJBX) Ex db IIB+H2 T… Gb Ex tb IIIC T… Db |
Cortem |
|
| IECEx |
GUB... CCA... |
Cassette per unità di segnalazione comando e controllo |
Ex db [ia Ma] I Mb (CCAI only) II 2GD Ex db [ia Ga] IIC Gb Ex tb [ia Da] IIIC T85°C Db |
Cortem |
|
| IECEx |
EJB-…AQS-2 |
Unità d'interfaccia |
II2(1)GD Ex db [ia Ga] IIB+H2 T…Gb Ex tb IIIC T…°C Db - IP66/67 |
Cortem |
|
| IECEx |
GUB... CCA... |
Unità d'interfaccia |
Ex db [ia Ma] I Mb Ex db [ia Ga] IIC T.. Gb Ex tb [ia Da] IIIC T…°C Db |
Cortem |
|
| IECEx |
CSC...EFD...EFSCO...EMH... |
Puls. e segn. Luminosi solo su corpo singolo |
II 2 GD Ex db I Mb Ex db IIC T6 T5 Gb Ex tb IIIC T85°C T100°C Db |
Cortem |
|
| IECEx |
CCA-03EX |
Armatura illuminante d'emergenza |
II 2GD Ex d IIC T6 Gb Ex tb IIIC T85°C Db |
Cortem |
|
| IECEx |
SA,CTB,CSTB,CTBE |
Cassette con proximitor o fieldbus |
Ex eb IIC T6/T5/T4 Gb Ex tb IIIC T85°C/T100°CDb |
Cortem |
|
| IECEx |
ECDE |
Drain valves |
II 2GD Ex eb IIC Gb Ex tb IIIC Db |
Cortem |
|
| IECEx |
M-0… |
Manovre |
Ex tb IIIC Db |
Cortem |
|
| IECEx |
EBL3040-1,EBL4040-2,EIL4040-1,EIF4040-1 |
Reattore e inverter |
Ex db IIC Gb |
Cortem |
|
| IECEx |
LFEE |
Armature illuminanti d'emergenza |
Ex db eb mb op is IIC T... Gb Ex tb op is IIIC T... Db |
Cortem |
|
| IECEx |
NAVP, PLG |
Cableglands and plugs |
Ex eb IIC Gb Ex tb IIIC Db
|
Other |
|
| IECEx |
NAV, NAVN, NAVF, NEV, NEVL |
Pressacavi per cavi armati e non armati |
Ex db IIC Gb Ex eb IIC Gb Ex tb IIIC Db Ex nR IIC Gc |
Cortem |
|
| IECEx |
TIGER... |
Proiettore Tiger 400 e scatola nR |
Ex II 3GD Ex nR II T2/T3 Ex tD A22 IP 66 |
Cortem |
|
| IECEx |
LFED |
Armature illuminanti d'emergenza |
Ex db op is IIB+H2 T6 Ex tb op is IIIC T72°C Db |
Cortem |
|
| IECEx |
YFC |
Finecorsa |
Ex II 2 GD Ex d IIC T6 Ex td A21 T85°C |
Cortem |
|
| IECEx |
EVML |
Armatura illuminante |
Ex eb mb op is IIC T.. Gb Ex tb op is IIIC T.. Db |
Cortem |
|
| IECEx |
EVL |
Armatura illuminante |
Ex db eb op is IIC T.. Ex tb op is IIIC T..°C Db |
Cortem |
|
| IECEx |
XLFE-MIA, XLFE-MIB, XLFE-LIB |
Armatura segnalazione ostacoli |
Ex db eb op is IIC T.. Ex tb op isIIC T..°C Db |
Cortem |
|
| IECEx |
LIFEX-M |
Armatura illuminante |
LIFEX-ME Ex db eb mb IIC T… Gb Ex tb IIIC T…°C Db LIFEX-MN Ex ec IIC T… Gc Ex tb IIIC T…°C Db |
Cortem |
|
| IECEx |
GRDE-4200 |
Sistema di messa a terra |
Ex db eb mb [ia Ga] IIC T6/T5 Gb Ex tb [ia Da] IIIC T85°C Db |
Cortem |
|
| ATEX |
UN..4,PLG..4,UN..7,NAVP,PLG..7,PT |
Pressacavi e tappi |
Ex II 2GD Ex eb IIC Gb Ex tb IIIC Db
|
Elfit |
|
| ATEX |
NAV, NAVN, NAVF, NEV, NEVL |
Pressacavi per cavi armati e non armati |
II 2G Ex db IIC Gb II 2G Ex eb IIC Gb II 2D Ex tb IIIC Db |
Cortem |
|
| ATEX |
NAV, NAVN, NAVF, NEV, NEVL |
Pressacavi per cavi armati e non armati |
II 3G Ex nR IIC Gc |
Cortem |
|
| ATEX |
RLFE |
Armatura illuminante |
II 2GD Ex de IIC T…Gb Ex tb IIIC T…°C Db |
Cortem |
|
| ATEX |
YFC |
Finecorsa |
II 2GD Ex d IIC T6 Ex tD A21 T85°C |
Cortem |
|
| ATEX |
GRDE-4200 GRDC-4200 |
Sistema di messa a terra |
Ex II 2GD Ex db eb mb [ia Ga] IIC T6/T5 Gb Ex tb [ia Da] IIIC T85°C Db |
Cortem |
|
| ATEX |
EJBC |
Componente |
Ex 2G Ex db IIC Gb II 2D Ex tb IIC Db I M2 Ex db I Mb |
Cortem |
|
| IECEx |
EJBC |
Componente |
II 2G Ex db IIC Gb II 2D Ex tb IIC Db I M2 Ex db I Mb |
Cortem |
|
| ATEX |
EJBC |
Conformità, unità d’interfaccia (barriere) |
Ex II 2G Ex db IIC T6..T4 Gb Ex II 2G Ex db [ia Ga] IIC T6..T5 Gb Ex II 2D Ex tb IIIC T85°C..T135°C Db Ex II 2D Ex tb [ia Da] IIIC T85°C..T100°C Db Ex I M2 Ex db I Mb Ex I M2 Ex db [ia Ma] I Mb |
Cortem |
|
| IECEx |
EJBC |
Conformità, unità d’interfaccia (barriere) |
Ex db IIC T6..T4 Gb Ex db [ia Ga] IIC T6..T5 Gb Ex tb IIIC T85°C..T135°C Db Ex tb [ia Da] IIIC T85°C..T100°C Db Ex db I Mb Ex db [ia Ma] I Mb |
Cortem |
|
| ATEX |
EVNL |
Armatura illuminante |
Ex II 2D Ex tb IIIC T…°C Db |
Cortem |
|
| ATEX |
EVNL |
Armatura illuminante |
Ex II 3G nR IIC T…°C Gc |
Cortem |
|
| IECEx |
EVNL |
Armatura illuminante |
Ex nR IIC T4…T6 Gc Ex tb IIIC T135…T85 °C Db |
Cortem |
|
| IECEx |
NAVB NEVB |
Pressacavi barriera |
Ex db IIC Gb Ex eb IIC Gb Ex tb IIIC Db Ex nR IIC Gc |
Cortem |
|
| ATEX |
SLED-M.. |
Proiettori |
Ex II 2GD Ex db eb IIB+H2 T.. Gb Ex tb IIIC T.. Db
|
Cortem |
|
| INMETRO |
SLED |
Proiettori |
Ex db eb IIB+H2 T.. Gb Ex nR IIC T.. Gc Ex tc IIIC T.. Dc
|
Cortem |
|
| TR CU |
EJB,EJBX |
Custodie di derivazione |
Ex db IIB Gb U Ex db IIB+H2 Gb U Ex tb IIIC Db U IP66/IP67 1Ex db IIB T6/T5 Gb X Ex db IIB+H2 T6/T5 Gb X Ex tb IIIC T85°C/T100°C Db X IP66/IP67 1Ex db IIB T6/T5/T4 Gb X Ex db IIB+H2 T6/T5/T4 Gb X Ex tb IIIC T85°C÷T135°C Db X IP66/IP67 |
Cortem |
|
| TR CU |
CCAE, CCAI, CCAIF, CCAC |
Custodie di derivazione |
Ex db IIC Gb U Ex tb IIIC Db U IP66 1Ex db IIC T6/T5 Gb X Ex tb IIIC T85°C/T100°C Db X IP66 1Ex db IIC T6/T5 Gb X Ex tb IIIC T85°C/T100°C Db X IP66 |
Cortem |
|
| TR CU |
M-0 Ex d |
Manovre |
Ex db IIC Gb U Ex tb IIIC Db U IP66 Ex db I Mb U |
Cortem |
|
| TR CU |
LIFEX |
Armature illuminanti |
|
Cortem |
|
| ATEX |
S.1 |
Scatole di derivazione |
Ex II 2GD Ex db IIC T..Gb Ex II 2GD Ex eb IIC T.. Gb Ex II 2GD Ex i IIC T.. Gb Ex tb IIIC T.. Db
|
Elfit |
|
| IECEx |
S.1, S, GUA, EAH |
Scatole di derivazione |
Ex db IIC T.. Gb Ex eb IIC T.. Gb Ex i IIC T.. Gb Ex tb IIIC T.. Db
|
Elfit |
|
| ATEX |
FLOWEX |
Armatura illuminante LED |
Ex db Ex tb
|
Cortem |
|
| ATEX |
FLOWEX |
Armatura illuminante LED |
Ex tb
|
Cortem |
|
| ATEX |
FLOWEX |
Armatura illuminante LED |
Ex nR
|
Cortem |
|
| IECEx |
FLOWEX |
Armatura illuminante LED |
Ex eb Ex tb Ex nR
|
Cortem |
|
| ATEX |
LIFEX-PE |
Armatura illuminante a LED |
Ex db eb mb Ex tb
|
Cortem |
|
| ATEX |
LIFEX-PN |
Armatura illuminante a LED |
Ex ec Ex nR
|
Cortem |
|
| IECEx |
LIFEX-P |
Armatura illuminante a LED |
Ex db eb mb IIC T.. Gb Ex eb mb IIC T.. Gb Ex ec IIC T.. Gc Ex nR IIC T.. Gc Ex tb IIIC T.. Db
|
Cortem |
|
| UKCA |
FLOWEX |
Armatura illuminante a LED |
Ex II 2G Ex eb mb IIC T.. Gb Ex II 2D Ex tb IIIC T.. Db
|
Cortem |
|
| UKCA |
FLOWEX |
Armatura illuminante a LED |
Ex II 2D Ex tb IIIC T.. Db
|
Cortem |
|
| UKCA |
FLOWEX |
Armatura illuminante a LED |
Ex II 3G Ex nR IIC T.. Gc
|
Cortem |
|
| UKCA |
LIFEX-P |
Armatura illuminante a LED |
Ex II 2GD Ex db eb mb IIC T..Gb Ex eb mb IIC T.. Gb Ex tb IIIC T.. Db
|
Cortem |
|
| UKCA |
LIFEX-P |
Armatura illuminante a LED |
Ex II 3G Ex ec IIC T.. Gc
|
Cortem |
|
| UKCA |
LIFEX-M |
Armatura illuminante a LED |
Ex II 2GD Ex db eb mb IIC T.. b Ex eb mb IIC T.. Gb Ex tb IIIC T.. Db
|
Cortem |
|
| IECEx |
RLFE |
Armatura illuminante |
Ex de IIC T.. Ex tb IIIC T..
|
Cortem |
|
| CCC |
S.1- S- GUA- EAH |
Cassette con morsetti |
Ex db IIC T..Gb Ex eb IIC T..Gb Ex ia/ib IIC T..Gb Ex tb IIIC T..Db
|
Other |
|
| CCC |
S.1- S- GUA- EAH |
Scatole vuote |
Ex db IIC Gb Ex tb IIIC Db
|
Other |
|
| TR CU |
|
Raccorderia |
|
Cortem |
|
| UKCA |
LIFEX-M |
Armature illuminanti |
Ex II 3G Ex ec IIC T.. Gc Ex II 3G Ex nR IIC T.. Gc
|
Cortem |
|
| ATEX |
CMD |
Pulsantiere di comando e segnalazione |
Ex II 2GD Ex db eb IIC T.. Gb Ex eb ia IIIC T.. Gb Ex ia tb IIIC T.. Db
|
Cortem |
|
| IECEx |
CMD |
Pulsantiere di comando e segnalazione |
Ex db eb IIC T..Gb Ex tb IIIC T..Db Ex eb IIC T..Gb Ex ia IIC T..Gb Ex eb ia IIIC T..Gb Ex db eb ib mb IIC T..Gb
|
Cortem |
|
| UKCA |
XLFE-MIB, XLFE-MIA, XLFE-LIB, XLFE-MIC |
Obstruction light |
Ex II 2GD Ex db IIC T..Gb Ex tb IIIC T.. Db Ex II 2GD Ex db eb IIC T.. Gb
|
Cortem |
|
| ATEX |
ESP |
Tubi flessibili |
Ex II 2GD Ex eb IIC Gb Ex tb IIIC Db
|
Other |
|
| UKCA |
GRDC-4200, GRDE-4200 |
Sistema elettronico capacitivo di messa a terra |
|
Cortem |
|
| IECEx |
ESP |
Tubi flessibili |
Ex eb IIC Gb Ex tb IIIC Db
|
Other |
|
| INMETRO |
SA... CTB |
Cassette di derivazione |
Ex db eb ib mb IIC T.. Gb Ex ia IIC T.. Gb Ex tb IIIC T.. Db
|
Cortem |
|
| UKCA |
CCAE;CCAC;CCAI;CCAIF;CCAIF H |
Custodie di derivazione |
Ex I M2 Ex db I Mb Ex II 2GD Ex db IIC T.. Gb Ex tb IIIC T.. Db
|
Cortem |
|
| UKCA |
CCA, CCAI |
Custodie di derivazione |
Ex I M2 Ex db [ia Ma] I Mb Ex II 2(1) GD Ex db [ia Ga] IIC T.. Gb Ex tb [ia Da] IIIC T.. Db
|
Cortem |
|
| IECEx |
FASTEX-M |
Connettori elettrici |
Ex eb IIC T.. Gb - Ex tb IIIC T..°C Db Ex ec IIC T.. Gc - Ex tc IIIC T..°C Dc
|
Other |
|
| ATEX |
FASTEX |
Connettori elettrici |
Ex II 2GD Ex eb IIC T6 Gb Ex tb IIIC T66°C Db
|
Other |
|
| UKCA |
FASTEX |
Connettori elettrici |
Ex II 2GD Ex eb IIC T.. Gb Ex tb IIIC T.. Db
|
Other |
|
| UKCA |
FASTEX |
Connettori elettrici |
Ex ec IIC T5 Gc Ex tc IIC T80°C Dc
|
Cortem |
|
| ATEX |
FASTEX |
Connettori elettrici |
Ex ec IIC T6 Gc Ex tc IIIC T66°C Dc
|
Other |
|
| IECEx |
SLED-M.. |
Proiettori |
Ex nR |
Cortem |
|
| UKCA |
SLED-ME |
Proiettori a LED ”square shaped beam” |
Ex II 2GD Ex db eb IIB+H2 T.. Gb Ex tb IIIC T.. Db
|
Cortem |
|
| ATEX |
SLED-MN |
Serie SLED-MN Proiettori a LED |
Ex nR |
Cortem |
|
| UKCA |
SLED-MN |
Serie SLED-MN Proiettori a LED |
Ex II 3GD Ex nR IIC T.. Gc Ex tc IIIC T Dc
|
Cortem |
|
| ATEX |
STREETEX |
Armatura stradale a LED |
Ex II 2GD Ex eb mb IIC T..Gb Ex tb IIIC T.. Db
|
Cortem |
|
| ATEX |
STREETEX |
Armatura stradale a LED |
Ex II 3G Ex nR IIC T..Gc
|
Cortem |
|
| IECEx |
STREETEX |
Armatura stradale a LED |
Ex eb mb IIC T..Gb Ex tb IIIC T.. Db Ex nR IIC T..Gc
|
Cortem |
|
| UKCA |
STREETEX |
Armatura stradale a LED |
Ex II 2GD Ex eb mb IIC T.. Gb Ex tb IIIC T.. Db
|
Cortem |
|
| UKCA |
STREETEX |
Armatura stradale a LED |
Ex II 3G Ex nR IIC T.. Gc
|
Cortem |
|
| UKCA |
EJB, AQS-1 |
Componente |
|
Cortem |
|
| UKCA |
M-0 |
Operatori |
|
Cortem |
|
| CCC |
EJB, EJBX, AQS-1 |
Conformità |
Ex db IIB+H2 T.. Gb Ex tb IIIC T.. Db
|
Cortem |
|
| CCC |
M-0 |
Operatori |
Ex db IIC Gb Ex tb IIIC Db
|
Cortem |
|
| ATEX |
PYN SPYN |
Prese e spine |
Ex db Ex eb Ex tb |
Cortem |
|
| IECEx |
PYN, SPYN |
Prese e spine |
Ex db eb IIC T.. Gb Ex tb IIIC T.. Db
|
Cortem |
|
| ATEX |
EBV-1 |
Reattore elettronico |
Ex II 2G Ex e mb IIC Gb
|
Cortem |
|
| IECEx |
NEVCF |
Pressacavi |
Ex db IIC Gb Ex eb IIC Gb Ex tb IIIC Db
|
Other |
|
| ATEX |
NEVCF |
Pressacavi |
Ex II 2GD Ex db eb IIC Gb Ex tb IIIC Db
|
Other |
|
| INMETRO |
FLF, FLFE |
Armatura con tubi a LED |
Ex db eb op is IIC T.. Gb Ex tb op is IIC T.. Db
|
Cortem |
|
| INMETRO |
RE, REB, REM, REN |
Adattatori |
Ex db IIC Gb Ex eb IIC Gb Ex tb IIIC Db
|
Cortem |
|
| ATEX |
ECD... |
Valvoline |
II 2G Ex d IIC Gb ( ECD-1...) II 2 G Ex d IIB Gb ( ECD-1...) II 2 GD Ex d IIC Gb (ECD-2...) Ex e IIC Gb (ECD-2...) Ex tb IIIC Db (ECD-2...) II 2 GD Ex d IIB Gb (ECD-2...) Ex e IIB Gb (ECD-2...)
|
Other |
|
| ATEX |
EJBX-6BB |
Componente |
Ex I M2 Ex db I Mb Ex II 2GD Ex db IIB+H2 Gb Ex tb IIIC Db
|
Cortem |
|
| IECEx |
EJB, EJBX, AQS-1 |
Componente |
Ex db IIB Mb Ex db IIB+H2 Gb Ex tb IIIC Db
|
Cortem |
|
| ATEX |
SA,CTB,CSTB,CTBE |
Cassette di derivazione zona 2 |
Ex II 3G Ex ec mc nA nC op is [ib Gb] IIC T.. Gc
|
Cortem |
|
| INMETRO |
CMBSP07 |
Plug and sockets |
Ex db eb IIC T.. Gb Ex tb IIIC T.. Db
|
Cortem |
|
| IECEx |
SA, CTB, CSTB, CTBE |
Cassette di derivazione zona 2 |
Ex ec mc nA Nc op is [ib Gb] IIC T.. Gb
|
Cortem |
|
| INMETRO |
NAV;NEV |
Pressacavi |
Ex db IIC Gb Ex eb IIC Gb Ex nR IIC Gc Ex tb IIIC Db
|
Other |
|
| ATEX |
EJBX-8 |
Cassette per unità di segnalazione comando e controllo |
Ex I M2 Ex db I Mb Ex II 2G Ex db eb IIB+H2 T.. Gb Ex II 2D Ex tb IIIC T.. Db
|
Cortem |
|
| IECEx |
EJB EJBX |
Custodie di comando, controllo e segnalazione |
Ex db I Mb Ex db IIB+H2 T.. Gb Ex tb IIIC T.. Db
|
Cortem |
|
| ATEX |
SA,CTB,CSTB,CTBE |
proximitor o fieldbus |
Ex II 2(1) GD Ex eb ib mb [ia Ga] IIC T4 Gb Ex tb [ia Da] IIIC T85°C Db
|
Cortem |
|
| INMETRO |
EBV-1 |
Reattore elettronico |
Ex eb mb IIC Gb
|
Cortem |
|
| INMETRO |
M-0530, M-0531 |
Blocco contatti |
Ex db eb IIC Gb
|
Cortem |
|
| INMETRO |
XLF XLFE |
Obstruction light |
Ex db eb IIC T.. Gb Ex tb IIIC T.. Db
|
Cortem |
|
| INMETRO |
GRDC-4200, GRDE-4200 |
Sistema elettronico di messa a terra |
Ex db eb mb [ia Ga] IIC T.. Gb Ex tb [ia Da] IIIC T.. Db
|
Cortem |
|